• Wed. Feb 19th, 2025

LabSyst

All for Scientific R&D

Copper Sulfate Reference Electrode (CCT Portable CUSO4) Copper Sulfate Electrode Cork-Ceramic Core 1 pcs

  • Home
  • Copper Sulfate Reference Electrode (CCT Portable CUSO4) Copper Sulfate Electrode Cork-Ceramic Core 1 pcs
Sale!

Copper Sulfate Reference Electrode (CCT Portable CUSO4) Copper Sulfate Electrode Cork-Ceramic Core 1 pcs

$44.49$49.95

Clear
SKU: 3256804352247188 Category:

Description

  • Type: Other
  • Origin: Mainland China
  • Material: Plastic
modname=ckeditor

option1 copper sulfate electrode wood wetted (cork) 1pcs

option2 copper sulfate electrode ceramic wetted (ceramic core) 1pcs

 

Specifications:Wood core wetted、Porous ceramic core wetted(New products)

1、purpose: Portable copper sulfate reference electrode is suitable for field use。It is mainly used to measure the natural potential and cathodic protection potential of underground metal pipelines,Determination of stray current in soil,It can also be used to measure the potential of cable metal sheath and reinforcement in concrete。The electrode is in the place with sticky soil,It can be used as a reference electrode for controlling potential in impressed current cathodic protection system。It can be used in all kinds of soil and fresh water。

2、structure performance

  (1)Small electrode volume,be easy to carry about。The cavity is composed of transparent nylon rods,It is convenient to observe the saturation of the internal copper sulfate solution。

  (2)Electrode potential stability,Electrode is not easy to polarize。

  (3)Long electrode life,The electrode cap is connected with the electrode cavity with a screw,Convenient solution filling。One time infusion can be used for more than one year。

  (4)The electrode structure is firm,Joint corrosion resistance,The leakage rate of microporous membrane is appropriate,No visible liquid flow,Can be placed in the pocket。

3、Use and maintenance of copper sulfate reference electrode

      First, the surface of the reference electrode should be kept clean,When not in use,Cover the multi hole plug with plastic bag or rubber cap,Avoid contamination。Then replace the copper sulfate inside regularly,And clean the rod with non-metallic abrasive materials;for example,Use silica sandpaper instead of alumina sandpaper to clean the copper bar,If the solution becomes turbid,Pour it out and replace it with a new copper sulfate solution。Ensure that there are still undissolved crystals in the solution;This saturated copper sulfate solution can prevent copper corrosion,So that the electrode is stable。In a polluted environment,After using the electrode,To maintain it。Contamination of chlorinated compounds can change chemical reactions。When the concentration is5pptWhen,Reference potential becomes yes-20mVMixed potential of deviation,The concentration is100pptWhen,Deviation reaches-95mV。During the construction of cathodic protection project,A reference electrode should be prepared for standby,If the electrode is lost,Then another reference electrode can be used to continue working。 

       When the reference electrode is used on site, another new electrode needs to be prepared,In order to calibrate whether the electrodes used on site are accurate。However, when the value measured by the calibration electrode is more than the value measured by the reference electrode being used on site5mVWhen,It is necessary to clean the electrodes used on the construction site。 

       Because of the temperature in the construction environment、The sunlight is different,Therefore, it is necessary to correct the change of potential。Potential correction for different temperatures,It is necessary to record the temperature while reading the value of the reference electrode。When the reference temperature value used is higher or lower than the actual temperature value,Be sure to add or subtract separately when recording0.5mV/°Fperhaps0.9mV/°CTemperature correction value of。 

       Shielding electrode is required in the measurement process of using reference electrode,Avoid direct sunlight,The transparent part on one side of the electrode can be covered with black tape。Different degrees of sunlight exposure,The value measured by the reference electrode will also be different,The potential of the reference electrode in a sunny environment is higher than that in a dark place without sunshine10reach50mV。 

       In a special environment, the reference electrode should also choose different types according to different environments,Such as the special reference electrode on the inner wall of the storage tank,It is used for the measurement of cathodic protection potential in the inner wall of storage tank or other water medium。The structure of this special reference electrode is to fix the pure zinc rod in a porous non-metallic shell,Ensure that the electrode does not have direct contact with the protected equipment。The potential of the special reference electrode on the inner wall of the storage tank is in the sleeve,To avoid direct contact with the wall,Electrode potential is-1.10V CSE,Potential stabilization,Drift or polarization less than5%,The structure protection potential should be lower than+0.25V。The main components of the special reference electrode on the inner wall of the storage tank are:A1less than0.005%,Cdless than0.003%,Feless than0.0014%,Culess than0.002%,Pbless than0.003%,ZnIs margin。1.Application of portable reference electrode: Portable copper sulfate reference electrode is suitable for field use。It is mainly used to measure the natural potential and cathodic protection potential of underground metal pipelines,Determination of stray current in soil,It can also be used to measure the potential of cable metal sheath and reinforcement in concrete。The electrode is in the place with sticky soil,It can be used as a reference electrode for controlling potential in impressed current cathodic protection system。It can be used in all kinds of soil and fresh water。

 

 

one、 Application characteristics

Portable copper sulfate reference electrode is suitable for field use。It is mainly used to measure the natural potential and cathodic protection potential of underground metal pipelines,Determination of stray current in soil,It can also be used as a reference electrode for controlling potential in impressed current cathodic protection system, and can be used to measure the potential of cable metal sheath and reinforcement in concrete。

The electrode can be used in places with sticky soil and in all kinds of soil and fresh water。

 

two、 structure performance

1、 Small electrode volume,be easy to carry about。The cavity is made of transparent plexiglass,It is convenient to observe the saturation of the internal copper sulfate solution。

2、 Electrode potential stability,The potential of calomel electrode under standard conditions is70±3mV,Conform to theoretical value,The potential difference between each other is less than±1mV。

3、 Electrode is not easy to polarize,When used on site,The potential difference between each other is less than±3mV。Internal resistance of electrode is less than3KΩ。

4、 Long electrode life,The electrode cap is connected with the electrode cavity with a screw,Convenient solution filling。One time infusion can be used for more than one year,As long as the cavity is not damaged,It can be filled many times,Long term use。

5、 The electrode structure is firm,Joint corrosion resistance,The leakage rate of microporous membrane is appropriate,No visible liquid flow,Can be placed in the pocket。

three、 usage method

1、Open the front cover of the reference electrode,Inject distilled water over copper sulfate particles2cmThen cover the front cover、Shake several times,Fully dissolve copper sulfate particles;

2、Put the vent plug of the reference electrode into clean water and soak it;

3、Insert the end of the reference electrode into the moist soil near the tested metal structure,Adjust the multimeter to2VGear range,The wire carried by the reference electrode is clamped to the black end of the multimeter;

4、The red line of the multimeter is clamped to the test line in the test pile,Read and record data。